Modified paramedian versus conventional paramedian technique in the residency training: an observational study

Abstract

Background

Residency training includes positive and negative aspects. Well-trained doctors must be educated, but the process may bring additional risks to patients. Anesthesiologists’ performance when conducting neuraxial anesthesia is related to their experience. We hypothesized that a modified neuraxial anesthesia method would improve both residency training and patient safety.

Methods

We recruited 518 patients who were scheduled for a cesarean section and used spinal anesthesia (n = 256), epidural anesthesia (n = 154), and combined spinal–epidural anesthesia (SEA; n = 108). We observed and evaluated the anesthesia performance of five second-year resident anesthesiologists in elective cesarean sections using the conventional and modified methods. The number of attempts, implant error rate, and the incidence of complications were recorded and analyzed.

Results

Better success puncture attempts occurred in all three groups when the modified method was applied. For the groups with an implant assessment, the complication rate and implant error rate were lower when using the modified method. We employed generalized estimating equation (GEE) analysis to correct for possible confounding factors. When using the conventional method, the resident anesthesiologists required more attempts, made more implant errors, and caused more complications in patients.

Conclusions

We found that a modified method for neuraxial anesthesia could improve residency performance and patient safety. The modified method may be a suitable training process for resident anesthesiologists when practicing neuraxial anesthesia.

Trial registration

The study was approved by the Research Ethics Committee of National Taiwan University (IRB:200812040R) Clinicaltrials register: NCT03389672.

Peer Review reports

Background

Residency training is performed using trial and error. Several studies have shown that the training process, practice period, and resident’s attitude are important factors for determining performance [1,2,3]. During the training process, neuraxial anesthesia safety is related to the operator’s experience. Ultrasound can improve resident performance [4,5,6,7]; however, using ultrasound technologies in well-established training programs may not be practical for all residencies.

Traditional midline and paramedian technique were general practice around the world. Lots of anesthesiologists in Taiwan proceed paramedian approach because paramedian approach bypasses most of the bony structures that may impede the advancement of a needle in the midline approach [8,9,10,11,12]. Previous study showed faster and better success via paramedian approach [9, 13, 14]. However, paramedian approach requires a sharpened three-dimensional insight compared with the midline approach, and needle may be hindered by the barrier when the it passed through the way far away from the midline. We would encounter inferior articular process and pedicle more close to needle pathway, and less inter-lamina foramen diameter in three-dimensional structure especially in obesity patients. We hypothesized that the farther away from the three-dimensional barrier, the better success rate and lower the complications and number of puncture attempts, as compared to a traditional paramedian approach. A modified paramedian approach, which compared to midline approach and traditional approach, was more away from the spinous process, and it may improve residency training and patient safety. The aim of this study was to investigate whether the modified method increased success rate and decreased practice attempts and patient complications.

Methods

To conduct this prospective study, we observed five resident anesthesiologists practicing regional anesthesia in 518 parturients who received spinal anesthesia (SA), epidural anesthesia (EA), or spinal–epidural anesthesia (SEA) for elective cesarean section from 1 January, 2011, to 30 September, 2012. The study was approved by the Research Ethics Committee of National Taiwan University (IRB:200812040R). All parturients received the information of spinal anesthesia, epidural anesthesia, and SAE anesthesia, and the study protocol. They were assigned to three groups SA, EA, or SEA group by randomized block method and enrolled into the study after they completed the inform consent before the procedure. All parturients in each groups were allocated to conventional method or modified method randomly (Fig. 1). The exclusion criteria were a history of allergy to the medications used in this study, chronic or acute headaches, possible conversion to general anesthesia, and other contraindications to practice (infection, coagulopathy, abnormal spinal anatomy, unstable vital signs, and refusal to participate in the study).

Fig. 1
figure 1

The flow diagram of study

Five second-year resident anesthesiologists had received training for spinal anesthesia, epidural anesthesia, and SEA in their first-year of residency training. The first-year training program included anatomic teaching and clinical performance. Each resident was assigned to performed one of the regional anesthesia via one method without having patients’ information, and the resident would practice the other method next time. All parturients who agreed to join the study were assigned to spinal, Iepidural, and SEA groups according to computer randomized-block number. One study nurse got a sealed-envelop recorded which group the patient was, without knowing other information. The nurse assigned each resident to the operation room to keep the ratio was 1:1 nearly in each group. According to our standard Direct Observation of Procedural Skills assessment and mini-Clinical Evaluation Exercise protocol, one supervisor recorded the measurements for each resident [15].

All parturients received 500 mL of Ringer’s lactate solution intravenously 30 min before anesthesia, after which their vital signs were monitored using equipment including an electrocardiogram, a blood pressure cuff, and an oximeter. Patients were sent to the operation room, and residencies waited in the operation room without knowing the patients’ data before the procedure. In the adopted method, the supervisor was blinded to the patients, surgeons, and anesthesiologists.

All parturients received regional anesthesia in the decubitus position, and the procedures were performed in the L3–4 or L4–5 interspace. The spinal anesthesia was administered using a 27-gauge spinal needle (Becton Dickinson) containing 12 mg of bupivacaine hydrochloride (Marcaine 0.5% Spinal Heavy). The epidural and SEA anesthesias were performed using a 17-gauge Weiss type needle (Becton Dickinson) containing 300 mg of lidocaine hydrochloride (2% Xylocaine injection) without epinephrine. In the SEA group, we performed both a spinal subarachnoid puncture and epidural catheter implant using a combined needle (17-gauge, B. Braun Espocan), and the patients only received an injection of 12 mg (2.2 mL) of bupivacaine hydrochloride into the spinal subarachnoid space. For the conventional method, the injection site was 1 cm lateral and 1 cm caudal to the spinous process, and the needle was directed 45o cephalad and medially to the epidural–subarachnoid space by the operator [16]. For the modified method, the injection site was 0.5 cm lateral, 0.5 cm caudal to the spinous process, perpendicular to skin, and the other process was the same as the conventional method.

Sample size evaluation

According to our knowledge, there was no previous study, and it was difficult to know adequate sample size. We tried to estimate sample size by using Chi-square test for power calculation. Before the study, our clinical experience has been considered for endpoints and study groups. We calculated the power at the end of study and result showed sufficient sample size (Table 1).

Table 1 Power analysis for Chi-square test: alpha = 0.05

Clinical measurement and outcome

The primary outcome of our study was the success rate of attempt with traditional paramedian or modified paramedian technique in all three groups. The secondary outcome included complications in all three groups and implant error in EA and SEA groups.

The number of attempts equated to the number of skin-to-site needle punctures before a successful needle puncture was achieved. Failure (represented by the failure rate) was determined when the number of attempts exceeded four. The success procedure was defined as regional anesthesia was completed at the first-attempt. The implant error rate was defined when a dura puncture occurred, when there was difficulty threading the catheter, or when intravascular catheterization or intrathecal catheterization occurred. Patient outcomes were recorded as all types of complications, including a post dura-puncture headache epidural hematoma, infection, or any unexpected neurologic injury.

Statistical analysis

Clinical data are expressed as number and percentage (n, %) for categorical variables, or mean ± standard deviation for continuous variables. We compared the demographic and clinical variables of the conventional method and the modified method by using the 2-sample independent t test for continuous variable, and the chi-square test for categoric variable. Because each physician performed the procedure on several study subjects as per our study design, we used generalized estimating equation (GEE) analysis with an independent working correlation matrix to address any correlation problems cause by the clustering of patients for the same operating physician [17,18,19], and odds ratio were presented to note the significance outcome. A 2-tailed value of p < 0.05 was considered significant. SAS statistical software (SAS System for Windows, version 9.4; SAS Institute, Cary, NC, USA) and SPSS version 22 (SPSS Inc., Chicago, Illinois, USA) were used in this study.

Results

Five second-year resident anesthesiologists performed 256 spinal anesthesias, 154 epidural anesthesias, and 108 SEAs during the study. Patient characteristics are shown in Table 2. There was no statistical difference in age, height, weight, and number of nulliparous or multiparous patients.

Table 2 Patient demographic and clinical characteristics

Across all three groups, using the modified method resulted in fewer attempts than using the conventional method, and residents had the highest number of successful first attempt (modified vs conventional, 59.38% vs 20.31% in spinal group, 64.94% vs 14.29% in epidural group, and 47.27% vs 15.09% in SEA group, p < 0.001), indicating that the success rate was higher for the modified method than the other anesthesia methods. The implant error rate in the modified method group showed a higher none-error rate in the epidural (modified vs conventional, 85.71% vs 51.95%, p < 0.001) and SEA groups (modified vs conventional, 87.27% vs 35.85%, p < 0.001). It showed that junior residents would make less iatrogenic injury via modified method. In the spinal anesthesia group, the complication rate was low using both methods with no statistical difference, whereas a significantly lower complication rate was noted in the modified method (1.3% in epidural group, p = 0.001, 3.64% in SEA group, p = 0.006) for the epidural anesthesia and SEA groups Complication is related to attempt and implant error, and our complication rate are compatible with other result (Table 3).

Table 3 Residency performance outcome and complication

To adjust for confounding factors such as operator, age, and parity, we applied GEE analysis to the results, which was adjusted for the operator, patient’s age, body mass index, parity, and interaction between age and body mass index. The results from the conventional method and the modified method are presented in Table 4. In all three groups, residents had higher Odd ratio for more than one attempt (5.763, 13.739, and 5.354 in spinal, epidural, and SEA group, respectively, p < 0.001). The higher Odd ratio of more than one attempt, implant error and complication indicated that junior residents might make patients suffer from more injury via conventional method.

Table 4 Association between conventional method versus modified method and clinical outcomes with controlling the factors by GEE

Discussion

In our study, the resident anesthesiologists had a higher success rate and lower complication rate when they used the modified paramedian method for spinal anesthesia, epidural anesthesia, and SEA. Resident anesthesiologists need practice and the ability to tolerate failure. Our modified paramedian method lowers the failure rate and accelerates resident competency [2]. One reason for this could be that the shorter distance between the needle puncture site and palpable interspinous space and the lower dimensional barrier significantly improve accuracy.

For the successful administration of neuraxial anesthesia, the primary goal is to direct the needle to the interlaminar space and avoid 3-dimensional obstacles such as the spinous process and lamina. With traditional paramedian method, the needle is directed 45o upward to the skin and directed to the midline of spinous process. The horizontal space is usually smaller between interspinous space than interlaminar space, and the spinous process might impede the needle when the insertion site wasn’t away from the midline. The modified technique might increase the probability of needle over the lamina ridge and entered the interlaminar space more easily (Fig. 2a, b, c). Cousins and Bromge described the different paramedian methods used to facilitate the needle walk over the superior ridge of the lamina into the interlaminar space [10]. The shorter skin-to-site distance enhanced the residents’ awareness of the position of the needle tip and helped them to avoid contacting bone structures.

Fig. 2
figure 2

Less three dimension obstacles in modified method (b) than in modified method (a). c It illustrated the differences of modified and conventional injection site

The paramedian approach might be more suitable than the midline approach in various aspects such as fewer dura punctures [11], a lower incidence of epidural catheter errors [8, 20], and an easier approach to continuous spinal anesthesia for older adults [21]. However, previous studies have reported that junior anesthesiologists required fewer attempts or no perceivable difference when they adopted the midline approach [22, 23]. In addition, the paramedian approach requires a larger needle insertion depth and a greater needle puncture angle than the midline approach, and the paramedian vertical measurement gradually diminishes at the L3–5 levels [10]. This approach may be more difficult for junior residents to perform. The modified method, however, was closer to the spinous process than the conventional method, which reserved the benefit of both the midline approach and the paramedian approach.

Our study had several limitations. For example, it was an observational study, and the residents were not assigned the procedure randomly. Second, we didn’t perform the statistic test between independent groups. Third, we couldn’t find previous study, and we didn’t calculate sample size in advance. At the end of study, we calculate the power and the sample size was sufficient. Fourth, it was not a multicenter study and statistical bias may exist in different area. In addition, we did not record the learning summation for the final technical maturation. Due to GEE and GLM have the same coefficients under minor correlation between groups in this study, we finally presented results of analysis using GLM. To our knowledge, it’s not discouraging clinical finding from this study.

Conclusion

Our modified method improves resident performance and causes fewer patient complications. To improve both residency training and patient safety, we recommend that the modified method to the paramedian approach should be adopted in clinical practice.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

SEA:

Combined spinal epidural anesthesia

SA:

Spinal anesthesia

EA:

Epidural anesthesia

References

  1. Ambardekar AP. Selecting anesthesiology residency candidates-beyond the numbers. J Clin Anesth. 2017;41:38–9.

    Article  Google Scholar 

  2. Rodrigues dOFG. The construction of learning curves for basic skills in anesthetic procedures: an application for the cumulative sum method. Anesth Analg. 2002;95(2):411–6.

    Google Scholar 

  3. Gavin Martin CKL, David B, MacLeod HE, El-Moalem DS, Breslin DH, D’Ercole F. A new teaching model for resident training in regional anesthesia. Anesth Analg. 2002;95(5):1423–7.

    Article  Google Scholar 

  4. Sahin T, Balaban O, Sahin L, Solak M, Toker K. A randomized controlled trial of preinsertion ultrasound guidance for spinal anaesthesia in pregnancy: outcomes among obese and lean parturients: ultrasound for spinal anesthesia in pregnancy. J Anesth. 2014;28(3):413–9.

    Article  Google Scholar 

  5. Shaikh F, Brzezinski J, Alexander S, Arzola C, Carvalho JC, Beyene J, Sung L. Ultrasound imaging for lumbar punctures and epidural catheterisations: systematic review and meta-analysis. BMJ. 2013;346:f1720.

    Article  Google Scholar 

  6. Perlas A, Chaparro LE, Chin KJ. Lumbar Neuraxial ultrasound for spinal and epidural anesthesia: a systematic review and meta-analysis. Reg Anesth Pain Med. 2016;41(2):251–60.

    Article  Google Scholar 

  7. Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010;19(4):373–8.

    Article  Google Scholar 

  8. Blomberg RGJA, Walther S. Advantages of the paramedian approach for lumbar epidural analgesia with catheter technique. A clinical comparison between midline and paramedian approaches. Anaesthesia. 1989;44(9):742–6.

    Article  Google Scholar 

  9. Leeda MSR, Arbous MS, Dahan A, Th Veering B, Burm AG, Van Kleef JW. Lumbar epidural catheter insertion: the midline vs. the paramedian approach. Eur J Anaesthesiol. 2005;22(11):839–42.

    Article  Google Scholar 

  10. Boon JMPE, Raath RP. A paramedian approach for epidural block: an anatomic and radiologic description. Reg Anesth Pain Med. 2003;28(3):221–7.

    Google Scholar 

  11. Blomberg RG. Technical advantages of the paramedian approach for lumbar epidural puncture and catheter introduction. A study using epiduroscopy in autopsy subjects. Anaesthesia. 1988;43(10):837–43.

    Article  Google Scholar 

  12. Rabinowitz ABB, Minville V, Chassery C, Pianezza A, Colombani A, Eychenne B, Samii K, Fourcade O. The paramedian technique: a superior initial approach to continuous spinal anesthesia in the elderly. Anesth Analg. 2007;105(6):1855–7.

    Article  Google Scholar 

  13. LE Franci P, Corletto F. Thoracic epidural catheter placement using a paramedian approach with cephalad angulation in three dogs. Vet Surg. 2012;41(7):884–9.

    Article  Google Scholar 

  14. Ahsan-ul-Haq MAS, Javaid S. Paramedian technique of spinal anesthesia in elderly patients for hip fracture surgery. J Coll Physicians Surg Pak. 2005;15(3):160–1.

    Google Scholar 

  15. John J, Norcini DWM. Assessment methods in medical education. Teach Teach Educ. 2007;23(3):239–50.

    Article  Google Scholar 

  16. Miller RD. Miller's anesthesia. 8th ed; 2015.

    Google Scholar 

  17. Liang K, Zeger SL. Longitudinal data analysis using generalized linear models. Biometrika. 1986;73:13–22.

    Article  Google Scholar 

  18. Ballinger. Using generalized estimating equations for longitudinal data analysis. Organ Res Methods. 2004;7(2):127–50.

    Article  Google Scholar 

  19. EE HGG, Eiden RD, Leonard KE. Analyzing family data: A GEE approach for substance use researchers. Addict Behav. 2010;35(6):558–63.

    Article  Google Scholar 

  20. Leeda M, Stienstra R, Arbous MS, Dahan A, Th Veering B, Burm AG, Van Kleef JW. Lumbar epidural catheter insertion: the midline vs. the paramedian approach. Eur J Anaesthesiol. 2005;22(11):839–42.

    Article  Google Scholar 

  21. Rabinowitz A, Bourdet B, Minville V, Chassery C, Pianezza A, Colombani A, Eychenne B, Samii K, Fourcade O. The paramedian technique: a superior initial approach to continuous spinal anesthesia in the elderly. Anesth Analg. 2007;105(6):1855–7.

    Article  Google Scholar 

  22. Kopacz DJ, Neal JM, Pollock JE. The regional anesthesia "learning curve". What is the minimum number of epidural and spinal blocks to reach consistency? Reg Anesth. 1996;21(3):182–90.

    Google Scholar 

  23. Sprung Juraj BDL, Jeffrey G, Jeffrey H, Edward M, Padmini T, Igor T. Predicting the difficult Neuraxial block: a prospective study. Anesth Analg. 1999;89(2):384–9.

    Google Scholar 

Download references

Acknowledgements

We thank the staff of the Biotechnology R&D Center at the National Taiwan University Hospital (Hsin-Chu branch) and Miss Hsiao Jung Tseng, MS (Department of Clinical Trial Center, Chang Gung Memorial Hospital) for their assistance in the statistical analyses.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

SC2, and LC contributed to the study design. CL and FS contributed to data collection and analyses. IT helped further data analyze. SC1 and LC interpreted the results and drafted the manuscript. All authors read and approved the final manuscript and take full responsibility for all aspects of the study.

Corresponding author

Correspondence to Li-Kuei Chen.

Ethics declarations

Ethics approval and consent to participate

The ethic commission board (Research Ethics Committee of National Taiwan University IRB200812040R) has approved that our research. We obtained written informed consent from our participants.

Clinicaltrials register: NCT03389672.

Consent for publication

Not Applicable (all image and picture is self-made and reports no identify data).

Competing interests

Not applicable.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, SH., Chen, SS., Lai, CL. et al. Modified paramedian versus conventional paramedian technique in the residency training: an observational study. BMC Med Educ 20, 211 (2020). https://doi.org/10.1186/s12909-020-02118-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12909-020-02118-0

Keywords