Table 3 Results of confirmatory factor analysis of the 32-item instrument (n = 500)

From: Development and validation of self-assessment instrument to measure the digital professionalism of healthcare professionals using social media

Fit Indices

Cut-off values

Measured values

1. Incremental Fit Measures

 • Normed fit index (NFI)

 > 0.08 -1

0.09 (good fit model)

0.936

 • Incremental fit index (IFI)

Near to 1

0.959

 • Relative fit index (RFI)

Near to 1

0.923

 • Tucker‒Lewis index (TLI)

Near to 1

0.950

 • Comparative fit index (CFI)

Near to 1

0.959

2. Absolute Fit Measures

 • Root mean square error of approximation (RMSEA)

0.08–0.1

0.05 (good fit model)

0.065

 • Goodness-of-fit index (GFI)

 > 0.08–1

0.09 (good fit model)

0.862

 • Observed normed χ2 (CMIN/df)

 < 5