Skip to main content

Table 1 Results of the placed PIV in OSCE 1 and 2

From: Deterioration in hygiene behavior among fifth-year medical students during the placement of intravenous catheters: a prospective cohort comparison of practical skills

N = 177

OSCE 1

OSCE 2

P-value

Score (Maximum = 10)

7.67 ± 1.707

6.27 ± 1.844

< 0.001**

Informing the patient

 The patient is not informed about the procedure

17 (9.6)

113 (63.8)

< 0.001*

 The patient is informed about the procedure

160 (90.4)

64 (36.2)

Preparation of the material

 More than one material or the sharp-safe is missing

49 (27.7)

50 (28.2)

< 0.001*

 At least one material is missing

23 (13.0)

68 (38.4)

 Complete and correct preparation of the material

105 (59.3)

59 (33.3)

Hygienic hand disinfection prior to patient contact

 No hand disinfection was performed before patient contact

13 (7.3)

111 (62.7)

< 0.001*

 Hygienic hand disinfection prior to putting on the medical gloves

164 (92.7)

66 (37.3)

Application and deposition of the tourniquet

 The tourniquet is not applied or disposed of correctly

11 (6.2)

20 (11.3)

< 0.001*

 The tourniquet is not applied, while the needle is pulled before disposing of the tourniquet

88 (49.7)

23 (13)

 The tourniquet is applied and disposed in the correct manner

78 (44.1)

134 (75.7)

Disinfection of the puncture site

 The puncture site is not disinfected, or it is palpated after the disinfection and prior to the venipuncture

16 (9)

79 (44.6)

< 0.001*

 The puncture site is correctly disinfected

161 (91)

98 (55.4)

30 s application time for the disinfectant

 Disinfectant has not acted for 30 s

6 (3.4)

47 (26.6)

< 0.001*

 Disinfectant has acted for 30 s

171 (96.6)

130 (73.4)

Venipuncture

 The vein is not punctured

9 (5.1)

52 (29.4)

< 0.001*

 The vein is punctured the second time

50 (28.2)

27 (15.2)

 The vein is punctured the first time

118 (66.7)

98 (55.4)

Needle safety while puncturing the vein

 The needle was touched or bent by the student

24 (13.6)

37 (20.9)

0.079

 The needle was neither touched nor bent by the student

153 (86.4)

140 (79.1)

Discarding of the puncture needle

 The needle is not discarded correctly

47 (26.5)

31 (17.5)

< 0.001*

 The needle is discarded immediately but not correctly

41 (23.2)

81 (45.8)

 The needle is discarded immediately and correctly

89 (50.3)

65 (36.7)

Fixation of the PIV

 The PIV is not fixated correctly

33 (18.6)

31 (17,5)

0.894

 The PIV is fixated correctly

144 (81.4)

146 (82.5)

Controlling and connecting the NaCl-infusion

 The infusion is neither controlled, nor connected to the PIV

44 (24.9)

24 (13.6)

< 0.001*

 The infusion is connected to the PIV, without prior control

44 (24.9)

27 (15.2)

 The infusion is controlled and connected correctly to the PIV

89 (50.3)

126 (71.2)

Structured work process

 The work process is not structured

7 (3.9)

22 (12.4)

0.025*

 The work process is partly structured

55 (31.1)

42 (23.7)

 The work process is structured

115 (65)

113 (63.8)

Hand disinfection after discarding the medical gloves

 Hands are not disinfected after discarding the medical gloves

70 (39.5)

159 (89.8)

< 0.001*

 Hands are disinfected after discarding the medical gloves

107 (60.5)

18 (10.2)

  1. *Statistically significant difference in this feature between OSCE 1 and 2 was determined using the McNemar-test.
  2. **Statistically significant difference in this feature between OSCE 1 and 2 was determined using the t-test.